Displaying hardware health status
The Health Status displays information about the hardware components of the IP VCR. To access this information, go to
Status > Health.
To reset these values, click
Clear. Refer to the table below for assistance in interpreting the information displayed.
Field Field description Usage tips
Fans Voltages
RTC battery
Displays two possible states:
OK
Out of spec
States indicate both
Current status and Worst status
seen conditions.
OK – component is functioning properly
Out of spec – Check with your support
provider; component might require
service
If the
Worst status seen column displays "Out of
spec", but
Current status is "OK", monitor the
status regularly to verify that it was only a
temporary condition.
Temperature
Displays three possible states:
OK
Out of spec
Critical
States indicate both
Current status and Worst status
seen conditions.
OK – temperature of the IP VCR is within
the appropriate range
Out of spec – Check the ambient
temperature (should be less than 34
degrees Celsius) and verify that the air
vents are not blocked
Critical – temperature of IP VCR is too
high. An error also appears in the event
log indicating that the system will
shutdown in 60 seconds if the condition
persists
If the
Worst status seen column displays "Out of
spec", but
Current status is "OK", monitor the
status regularly to verify that it was only a
temporary condition.