Tektronix OA 5000 TV Cables User Manual


 
OA 5000 Series User Manual A --- 3
Appendix B: Specifications
The performance characteristics described in this appendix (Tables A-1
through A-3) are valid under the following conditions:
H The instrument must have been calibrated at an ambient temperature
between +20_ C and +30_ C.
H The instrument must have had a warm-up period of at least 20 minutes.
H All optical connections to the instrument are made using physical con-
tact connectors. Tektronix offers limited selection of fiber optic jumper
cables which utilize physical contact on the connector ends (for exam-
ple: Tektronix part number 174-1387-00, see Appendix A).
H Both input and output connectors have been cleaned as described on
page A---15.
Table A -1: Optical Characteristics
Characteristic
Specification
Wavelength Range OA 5002 1100 --- 1600 nm
OA 5012/22/32 750 --- 1600 nm
Input
OA 5002
OA 5012
OA 5022
OA 5032
Single Mode Fiber
50 m Multimode Fiber
62.5 m Multimode Fiber
100 m Multimode Fiber
Insertion Loss
750 --- 1100 nm
1100---1350 nm
1350---1600 nm
4.0 dB (OA 5012/22/32 only)
2.0 dB
2.5 dB
Return Loss
OA 5002
OA 5012/5022/5032
--- 45 dB
--- 25 dB
Attenuation Range
OA 5002
1100 --- 1350 nm
1350---1600 nm
OA 5012/22/32
750---1350 nm
1350---1600 nm
60 dB (calibrated, 0.01 dB step size)
50 dB (calibrated, 0.01 dB step size)
60 dB (calibrated, 0.01 dB step size)
50 dB (calibrated, 0.01 dB step size)
Maximum Attenuation
OA 5002/5012/5022
OA 5032
100 dB (shutter activated)
90 dB (shutter activated)
Repeatability ±0.05dB