Univex PRV-LX1 DVD Recorder User Manual


 
74
PRV-LX1
En
Importing Image Data, Edit Lists
Edit List File Format
Edit list files are text files with the .edl filename extension. Composition is as follows:
Header: PIONEER-DVDRec-EDL 002 ENCODING=XXX
Entry: Number Operation Type Parameter 1 Parameter 2 Parameter 3
The number of parameters differs depending on the type of operation involved. Numbers are consecutive
numerals beginning from 001.
Use a single-byte space (0x20) or tab (0x09) between [PIONEER-DVDRec-EDL] and [002]. Alternately, a carriage
return character (0x0A, 0x0D0A, 0x0D) may also be used.
The message ENCODING=XXX indicates the character encoding, and may be omitted.
The XXX represented here supports utf8, eucJP, Shift-JIS, and JIS7. If the command is omitted, utf8 will be
used as default encoding.
IN/OUT Point Setting Entry
Number Operation Type Parameter 1 Parameter 2 Parameter 3
NNN REC IN Point OUT Point Post-REC action
The IN/OUT point is set using time code format as follows: HH:MM:SS:FF
Post-REC action will indicate either STOP or PAUSE.
The final IN/OUT point setting entry in an edit list must always designate the post-REC action as STOP.
Chapter Point Setting Entry
Number Operation Type Parameter 1
NNN CHP CHAPTER POINT
The chapter point is designated using time code as HH:MM:SS:FF. The chapter point description must come
immediately below the IN/OUT point setting to which it is applied. Also, the Number value is given as that
given to the IN/OUT point setting entry.
DVD-RW disc initialization
Number Operation Type
NNN INI
Initialization can be applied only at the head of an edit list entry.
Finalize
Number Operation Type
NNN FNL
Finalizing can be applied only as the final entry of an edit list.
Wait
Number Operation Type Parameter
NNN WAI Comment
The wait command can be used within a list, to designate points necessary to change a VTR tape, etc.
If a comment is input, the comment will appear in the wait dialog.
If the comment is separated by a tab (0x09), it will appear split into two lines at the point of the tab.
Designating the Encoding Parameter
Number Operation Type Parameter 1 Parameter 2
NNN SET Rate Filter
Rate is R:n (n= 1-32)
Filter is F:n (n= 0-16)
This setting will continue to be reflected after EDL execution.