3Com DUA1800-0AAA04 TV Video Accessories User Manual


 
DUA1800-0AAA04
LinkBuilder ECS Modules 3-23
to which Bus the module is routed:
Link set to LK1 - Module routed to Bus E1
Link set to LK2 - Module routed to Bus E2
Link set to LK3 - Module routed to Bus E3
Note that the Bus can also be set via management.
2
Set link LK4 as follows:
If you are fitting the converter to any ECS module
except
the
local bridge module (3C1205x), leave LK4 at its default
position NORMAL.
If you are fitting the converter to the ECS local bridge module
(3C1205x), move LK4 to the alternative position BRIDGE
3
With the module and the converter oriented as shown in Figure
3-7 opposite, press the 96-way connector on the module firmly
into the socket on the converter.
The converter comes with both plates already attached to the
converter. The two screws fixing the plates to the converter
should not be removed, and are covered by labels to prevent this.
4
Secure the module to the converter by locating the two screws on
the module side of the converter and tightening fully.
.
Chassis.bk : CHAPTER3 Page 23 Monday, February 10, 1997 1:11 PM