37
13.2 Administer Iris Tables
Create new Iris Tables
● Click on the headword „<new>“ in the User Iris List
and click „Edit Iris Table“. This will start the Iris Table
Wizard. See chapter 13.3 to use the Wizard.
Load Iris Tables
● Click on the Iris Table in the User Iris List.
● Click „Load Table“.
● Insert the lens into the camera lens mount.
● Connect the lens motor to the LDB or UMC-3
● Click on „CAL“ to calibrate the lens.
Remove Iris Tables from the User Iris List
● Click on the Iris Table in the User Iris List.
● Click „Remove“. The Table will disapear from the
User Iris List but will remain stored in the User
Folder System.
Note:
To keep the lens list as clear as possible, store only
the currently and frequently used lenses in the User Iris List.
Add Iris Tables from the User Folder System
● Click on „Add Existing“
● In the User Folder System Menu, click on the desired
Iris Table.
● Click on „Open“. The Iris Table will appear in the
User Iris List.
Erase or Rename Iris Tables
● Click on „Add Existing“
● In the User Folder System Menu, double-click on the
desired Iris Table.
● From the PopUp Menu select „Delete“ or „Rename“
Note: Deleting an Iris Table from the User Folder
System can not be made undone.
Loaded Table Status Line
Displays the last Iris Table that was uploaded to the
LCS Unit. The Iris Table will remain stored in the
LCS Unit memory (LDB, FEM-2, UMC-3, 416 Plus
etc.) even after powering off the unit.
CAL Button
Click on the „Cal“ button to calibrate the lens.
Lens Manager Menu