Brocade Communications Systems S3-1002483-03 Home Theater Server User Manual


 
102 Brocade BigIron RX Series Hardware Installation Guide
53-1002483-03
Monitoring the status of an I2C failure on a management module
5
At the first occurrence of an I2C failure in the system, the Global I2C Error Indicator (GIEI) flag is
set. The GIEI severity is set to major on the first occurrence of an error detection. The GIEI flag is
cleared only if the management module is able to access the same exact physical device
successfully. The GIEI severity flag is set to minor only if other I2C devices are accessible. A set of
static and dynamic syslog messages are generated when any one or all of the following events
occurs:
When an I2C failure is first detected
When the GIEI severity is changed from major to minor
When the GIEI flag is cleared
The Syslog messages are generated in both the static and dynamic sections of the show logging
command output. A syslog message is also sent to the SNMP log server.
When the GIEI set to major, the first syslog is displayed as an Alert syslog message. The following
example displays an Alert syslog message when the GIEI is set to major:
The syslog message contains the following information about the failed device, and last successful
I2C access by the management module:
Current state of the GIEI flag
Severity of the failure: major or minor
MUX index number:
- 0-1, there are total of 2 MUX indexes in the BigIron RX chassis
- MUX index is always zero for the BigIron RX-4, BigIron RX-8, and BigIron RX-16 chassis
MUX tap number:
- 0-7, there are a total of 8 MUX taps per index
- 15: MUX tap is non applicable
Device ID
Device address
Description of the load
BigIron RX# show logging
Sysloglogging: enabled (0 messages dropped, 0 flushes, 1 overruns)
Buffer logging: level ACDMEINW, 50 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Static Log Buffer:
Apr 16 18:21:25:A:System: Power Supply 2 , middle, Not Installed (FAILED)
Apr 16 18:21:25:A:System: Power Supply 3 , top, Not Installed (FAILED)
Apr 16 18:21:25:A:System: bad i2c access (GIEI = set), Severity Major, Mux
index 0, Muxtap 4, ID 0x4, Addr0x5, (FANTRAY4)
Apr 16 18:21:25:I:System: last good i2c access, Muxindex 0, Muxtap 1, ID
0x9, Addr0x1, (SNM1TEMP)
Dynamic Log Buffer (50 lines):
Apr 16 18:21:25:A:System: bad i2c access (GIEI = set), Severity Major, Mux
index 0, Mux tap 4, ID 0x4, Addr 0x5, (FANTRAY4)
Apr 16 18:21:25:I:System: last good i2c access, Mux index 0, Mux tap 1, ID
0x9, Addr 0x1, (SNM1TEMP)
Mar 28 12:36:47:A:System: Set fan speed to MED (75%)
Mar 25 21:40:47:A:System: Set fan speed to MED-HI (90%)