Upgrading images independently
6
.
SL M1: RX-BI-MR Management Module Standby (Serial #: SA36060509, Part #:
35524-000B):
Boot : Version 2.7.3T145 Copyright (c) 1996-2010 Brocade Communications
Systems, Inc.
Compiled on Jun 12 2010 at 01:44:54 labeled as rmb02703b394
(439602 bytes) from boot flash
Monitor : Version 2.7.3T145 Copyright (c) 1996-2010 Brocade Communications
Systems, Inc.
Compiled on Jul 9 2010 at 09:35:50 labeled as rmb02703b413
(439602 bytes) from code flash
IronWare : Version 2.7.3T143 Copyright (c) 1996-2010 Brocade Communications
Systems, Inc.
Compiled on Jul 9 2010 at 09:41:14 labeled as rmpr02703b413
(4528285 bytes) from Primary
Board ID : 00 MBRIDGE Revision : 21
916 MHz Power PC processor (version 8003/0101) 166 MHz bus
512 KB Boot Flash (AM29LV040B), 32 MB Code Flash (MT28F128J3)
512 MB DRAM
Standby Management uptime is 12 days 2 hours 51 minutes 45 seconds
.
.
.
The output indicates that the management module currently has MBRIDGE Revision: 21 installed.
Upgrading the MBRIDGE FPGA image
Follow the steps given below to upgrade one or more MBRIDGE FPGA images on a BigIron RX
Series management module.
1. Place the new MBRIDGE FPGA image on a TFTP server to which the BigIron RX Series system
has access or on a PCMCIA flash card inserted in slot 1 or 2.
2. Copy the MBRIDGE FPGA image from the TFTP server or a flash card in slot 1 or 2 to all
management modules or a management module in a specified chassis slot. To perform this
step, enter one of the following commands at the Privileged EXEC level of the CLI (example:
BigIron RX
#):
copy tftp mbridge <ip-addr> <image-name> MBRIDGE
copy slot1 | slot2 mbridge <image-name> MBRIDGE
3. After the MBRIDGE upgrade is complete, the management module must be power-cycled.
4. Verify that the MBRIDGE images have been successfully copied to the specified interface
modules by entering the following command at any level of the CLI:
show version
Check for the MBRIDGE image version numbers in the output.
Hitless Layer 2 OS upgrade
Version 02.3.00a and later of the Multi-Service IronWare software support hitless upgrade of the
operating system on a BigIron RX switch.