Brocade Communications Systems S3-1002483-03 Home Theater Server User Manual


 
86 Brocade BigIron RX Series Hardware Installation Guide
53-1002483-03
Managing the cooling system
4
Fan Speed Med-Hi: 51 - 60
Fan Speed Hi: 56 - 85
state = 0 (FAN_STATE_LOW)
max_ts_shut_off_count = 3
shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_STANDBY_MP) ===
Fan Speed Low: -1 - 60
Fan Speed Med: 57 - 70
Fan Speed Med-Hi: 67 - 80
Fan Speed Hi: 77 - 85
state = 0 (FAN_STATE_LOW)
max_ts_shut_off_count = 3
shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_MP_CPU) ===
Fan Speed Low: -1 - 60
Fan Speed Med: 57 - 70
Fan Speed Med-Hi: 67 - 80
Fan Speed Hi: 77 - 85
state = 0 (FAN_STATE_LOW)
max_ts_shut_off_count = 3
shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_STANDBY_MP_CPU) ===
Fan Speed Low: -1 - 60
Fan Speed Med: 57 - 70
Fan Speed Med-Hi: 67 - 80
Fan Speed Hi: 77 - 85
state = 0 (FAN_STATE_LOW)
max_ts_shut_off_count = 3
shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Syntax: show fan-threshold
The display shows the following information:
TABLE 20 Temperature threshold information for modules and fan speeds
This field... Displays...
Thermal Sensor Control Block
(THERMAL_SENSOR_TEST_RULE_<mod
ule>)
The temperature threshold information for the various modules. The
<module> parameter indicates the following:
MP – The active management module
STANDBY_MP – The standby management module
SNM – The switch fabric module
LP – An interface module
Fan Speed Low or Med or Med-Hi or Hi The current setting of the low and high temperature thresholds for the
low, medium, medium-high, and high fan speeds.
NOTE: As indicated in Table 19 on page 84, the low fan speed for each
module does not have a default low temperature threshold
value, nor can you configure this value. The “-1” value that
appears in the Fan Speed Low field for each module is a
Brocade internal value only.
State = 0 (FAN_STATE_LOW) For Brocade internal use only.
max_ts_shut_off_count