EverFocus EKR-KB1 DVR User Manual


 
Page 86 MNNCEKRKB1_0439
6.12 Panasoni c Dome
6.12.1 Reference m aterial and documents
Dome Panasonic WV-CS600 e Panasonic WV-CS850
Protocol Information WV-CS850 ver 2.2, Nov.28, 2001
Protocol Information WV-CSR600, WV-CSR400, WV-BSR300 ver 5.3, Nov.27, 1997
6.12.2 Important p rotocol note
The Panasonic protocols allow the control of a range of domes with different features. As the protocols have
been wholly implemented the following commands can be used both for the WV-CS600 and WV-CS850 models
or they’re peculiar of only one model. Where possible, this difference has been specified in the following
paragraphs. In any case, check in the dome instruction manual for the available functions list.
6.12.3 Connection
6.12.3.1 Cable
White
Yellow
RS485A
RS485B
Yellow
Green
Panasonic WV-CS600
Panasonic WV-CS850
6.12.3.2 Dome settings
Warning! Even though the two Panasonic dome control protocols (Panas600 and Panas850) are compatible to
a certain degree, to achieve better control of the dome we advise choosing the more suitable.
Set “Conventional protocol”, LOCAL (not REMOTE)
8 data bits, no parity, 1 stop bit, Full Duplex
Wait time = 0
Dome ID-number must be set according to the respective installation manual.
Baudrate can be selected among the following values: 2400, 4800, 9600, 19200 (default) baud.
6.12.3.3 Keyboard settings
During Keyboard setup, submenu
 must be suitably set:




Panasonic 600
Baudrate must be equal to the one selected for the dome.




Panasonic 850
Baudrate must be equal to the one selected for the dome.