Konica Minolta VIVID 9i Universal Remote User Manual


 
62
Chapter
2
File
Menu
910
File – Import – Digitizer – Step Scan (When VIVID 910 is Selected)
10
Click the [Scan] button to acquire the
first scan data.
A scan will start, and a color image will be
displayed in the Work window area.
M
emo
If [Use Color] is not checked (i.e. no check mark is
shown), the scan data has no color image data, and a gray-
scale image will be displayed instead of a color image.
If the [Auto Scan] checkbox is checked, the
second and subsequent scans will be carried out
automatically.
If the [Auto Store] checkbox is checked, a store
will be carried out automatically at the end of
scan.
Clicking on the following radio buttons will
make a change to the image displayed in the work
window. The data acquired during the scan will
remain unchanged.
Item Explanation
[Mono] radio
button
The current image is displayed in
monochrome.
[Color] radio
button
The color image acquired from
the scan is displayed.
[Pitch] radio
button
The distance data is displayed
in the color that is shown in the
Near-Far color slide bar ac-
cording to the distance from the
object to the digitizer.
Clicking the [Color Read] button will re-scan for
the color data only. The distance data will not be
updated.
Clicking the [Edit] button enables you to delete
the area that is not necessary for three-dimen-
sionalization by specifying it using the mouse.
Messages will appear at the bottom of the Work
window area as shown right, so follow them to
operate the mouse.
Click the [Edit] button again to exit the edit mode.
Switch to pitch display screen, and right-click on
desired position in the screen while holding down
[CTRL] key. The Z-axis coordinates at that posi-
tion (distance from VIVID 910) will appear.
To specify distance manually and perform mea-
surement, this value must be used.