Maxtor MV-DR3000 DVR User Manual


 
64
3.1.8 EXCEPTION PARAMETER.
In the EXCEPTION setting page, press the SEARCH button to enter the EXCEPTION
PARAMETER setting page. In the PARAMETER EXCEPTION setting page, press the
SEARCH button to return to the EXCEPTION setting page.
For each EXCEPTION, the user can set the following parameters.
3.1.8.1 CNT ( Count ) 0..99
When the number of exceptions exceeds this number, the DVR will generate an
ALERT event. If this number is set as 0, any exception will be ignored.
3.1.8.2 RST ( Reset Time ) 0..24
If no exception has been detected for a certain number of hours, the Exception count
( in 3.1.8.1) will be reset to 0.
3.1.8.3 BUZ ( Buzzer ) Off/ On.
If the BUZ has been set as ON, the DVR will generate a buzzer sound as a warning
when an exception has been detected. The duration depends on the DWELL setting
( 3.1.8.7 ).
.
Note: The buzzer setting in SYSTEM/ BUZZER must also be set as ON, or the
function will not take effect.
3.1.8.4 FLG ( Flag ).
If the FLG has been set as ON, the DVR will show a mark ( *) on the screen, and
keep flashing for a duration depending on the setting in DWELL( 3.1.8.7 ).
3.1.8.5 NFY ( Notify Remote ).
If the NFY setting has been set as ON, the DVR will notify the remote viewer software
when the ALERT event has been generated. At the same time, a message “ALT” will
be shown on the screen.
3.1.8.6 FTP.
If the FTP setting has been set as ON, the DVR will start to send pictures to an FTP
server after the ALERT event has been generated. The rate is fixed at 1f/ 1s, and the
duration is 10 sec.
Note: The settings in the FTP SETTING must also be properly set, or the function will
not take effect. The FTP SETTING/ FTP MODE item must be set especially as
EXCEPTION.