49
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations
ENGLISH
Emergency Recording Setup
This item is used to set the emergency recording settings.
When the EMERGENCY terminal is grounded by the alarm
sensor while both of the MAIN switch on the rear panel
and the POWER button on the front panel are turned ON,
emergency recording starts automatically overriding all the
other settings even during timer recording or the unit is in
stop mode.
• Emergency recording is not performed while the MAIN
switch or POWER button is turned OFF or while timer
recording stand-by mode.
• The setting of the <Recording> menu cannot be
changed during normal recording or alarm recording.
When changing setting during recording, stop
recording for normal recording. For alarm recording,
when the “Alarm Input” in the <Recording> menu is
set to “Off,” the alarm input cannot be accepted for 5
minutes. When you stop recording during this time,
the setting change of the <Recording> menu is
available.
Setup Menu
Recording1
Emergency Recording Setup
5
Emergency Record Settings
D
step1. Select the frame or field recording.
step2. Set the long pre-alarm recording time in “Pre-alarm
Duration.”
0 min: Does not execute the long pre-alarm
recording.
step3. Set the emergency recording time in “Post-alarm
Duration.”
step4. Set the maximum recording rate.
step5. Set the recording camera.
• The button function changes between “All Off”
and “All On” each time you select this button.
step6. Select “Execute.”
• The preview screen appears.
Emergency recording
1) Uses all the camera of which number is set in
<Emergency Recording Setup> menu and of which
alarm recording rate is set in the alarm recording setting
screen.
The picture grade is “Super” and the recording rate is
set to the value obtained by dividing the maximum
emergency recording rate by the number of available
cameras.
• When power failure occurs during emergency
recording, the emergency recording is cancelled after
returning from the power failure.
• When emergency recording is input during timer
recording, the end time of the timer recording is
extended until the emergency recording is completed.
The timer recording is completed after completing the
emergency recording.
2) Cameras to be used
All the cameras which are set for emergency recording,
set for that time period, and set the recording and alarm
recording rate to other than “– – –” are used.
3) During emergency recording:
•“E-REC” is displayed on the screen in red.
• The camera number buttons and camera number dis-
play on the screen which are used for emergency re-
cording flash.
4) Emergency recording is registered in the alarm list and
displayed in magenta.
Long pre-alarm recording
Long pre-alarm recording is a function to perform pre-alarm
recording for a maximum of 60 minutes before the emer-
gency recording is started.
• To perform long pre-alarm recording, set the desired
capacity in “Long Pre-Alarm Area” (System
Menu Memory Data Management Setting for Main
Memory Change Partition Setting).
• When the long pre-alarm recording is started during
normal recording, not all the camera numbers set for
long pre-alarm recording may be used for recording.
• To perform the long pre-alarm recording by all the
camera numbers set for emergency recording:
i) To perform with normal recording:
Set all the desired cameras for normal recording.
Long pre-alarm recording is performed at the
picture grade of “Super” regardless of the setting
and at the recording rate set for normal recording.
ii) To perform with normal and alarm recordings:
Set the “Alarm Mode” to “Alarm Plus.”
(Normal recording) Set all the desired cameras for
normal recording. Long pre-alarm recording is
performed at the picture grade of “Super”
regardless of the setting and at the recording rate
set for normal recording.
(Alarm recording) During alarm recording, long pre-
alarm recording is performed at the picture grade
of “Super” regardless of the setting. And for only
the cameras used for alarm recording, long pre-
alarm recording is performed at the alarm recording
rate.
iii) To perform with alarm recording:
Set the “Alarm Mode” to “Alarm Plus.”
Long pre-alarm recording is performed at the
picture grade of “Super” regardless of the setting
and at the recording rate set for alarm recording.
• Long pre-alarm recording is executed with the
recording rate of the normal or alarm recording set
for that time period and with the picture grade of
“Super.”