Mitsubishi Electronics SW0D5C-CNVW-E Cable Box User Manual


 
4 - 22 4 - 22
MELSOFT
4 CONVERTING TEXT,CSV FORMAT DATA TO GX Developer FORMAT
DATA
4.3 Handling of conversion errors
This section explains the corrective actions when a conversion error is generated when
data in TEXT, CSV format is import by the GX Developer.
(1) Conversion error display
3)
1) 2)
Caution
• About the error line for an Instruction or I/O (Device)
error
If an I/O (Device) error occurs when multiple I/O (Device)
exist for a single instruction, the line number for the
Instruction will be displayed as the error line number.
Verify or save the conversion error.
First perform the following operations, then correct
the conversion error.
1) To save the conversion errors
Save the conversion error contents to a
specified file by clicking on the Save
button.
Up to 100 occurrences (lines) of errors can be
saved.
2) To discard conversion errors
Click the OK
button to end the conversion
processing and then close the GX Converter.
3) Up to 100 occurrences (lines) of conversion
errors will be displayed.
When the number of conversion errors
exceeds 100 occurrences (lines), the message
"Convert error counter is over 100. Cancelled
over 100 errors" will be displayed on line
number 101.
See Appendix 2, "Conversion error message
List" for detailed explanations of error
messages.
Ends the conversion
processing and closes
the GX Converter.