RECORDING IMAGES IN THE ALARM
RECORDING AREA
Pre-alarm recording
Insert the power cord into a wall outlet and turn on the
power.
The POWER indicator illuminates, and after approximately 15 seconds, the
EXIT/OSD indicator illuminates. The camera images appear on the monitor,
and the operating display appears in the top-left corner of the screen.
Note: The operating display can be moved or switched off by pressing the
EXIT/OSD button repeatedly.
See page 11 for details of the operating display.
Setting the time
Press the MENU button to display the LANGUAGE/CLOCK SET menu, and
set the date and time. After the setting has been made, press the EXIT/OSD
button, the date and time appear in the operating display. (See page 40.)
Set pre-alarm recording.
Press the MENU button to display the ALARM REC MODE SET menu. Set
ALARM RECORDING to the desired alarm recording setting (example:
MODE1). The *** setting for PRE-ALARM RECORDING will be set to
“OFF”, so change it to “ON”. (See page 54.)
Press the EXIT/OSD button to return to the normal screen. “PRE” appears in
the operating display, the ALARM indicator illuminates and pre-alarm
recording starts (the a mark does not appear).
The same monitored image as in the normal recording area is recorded
repeatedly in the alarm recording area.
Recording onto the hard disk proceeds automatically (default setting)
according to the following settings. The settings can be changed between
long-period recording and high-quality recording in five steps. (See page 47.)
•
Hard disk recording areas:
Normal recording area: 80%
Alarm recording area: 19%
Archive area: 1%
•
Picture quality: EN (Enhanced)
•
Recording method: Field
•
Recording speed: 0.12 seconds (65H)
POWER
EXIT/OSD
1
Operating display
01-01-01
00:00:00 EN 0.12SEC
MENU
2
<MAIN MENU 1>
1.LANGUAGE/CLOCK SET ->
2.VIDEO INPUT SET ->
3.RECORDING AREA SET ->
4.RECORDING CONDITIONS SET ->
<LANGUAGE/LANGUE/SPRACHE/IDIOMA>
ENGLISH
<CLOCK SET>
01-01-2001 MON 00:00:00
SS
REC/STOP
ALARM
3
<ALARM REC MODE SET>
PICTURE QUALITY : ENHANCED
FRAME/FIELD RECORDING : FIELD
AUDIO RECORDING : OFF
ALARM RECORDING : MODE1
REC CYCLE : 0.12SEC. DURATION: 1SEC
PRE-ALARM RECORDING : ¤¤¤
REC CYCLE : ¤¤¤ SEC. DURATION: ¤¤¤
=> (55682 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
10-05-01 PRE 0000