Clarity SN-4620-1080 Flat Panel Television User Manual


 
17
remote, press MENU. Using the up and down arrows, move
to Advanced Options and select Serial Port Settings.
w
In the Serial Port Settings menu, set the Group ID and
the Unit ID so that the combined ID is unique for each
Bay Cat X in this RS232 loop.
Addressing Bay Cat X
Part of the RS232 command will be an address. This
address may take several forms. For example, suppose we
have 8 units in one area divided into two groups. We might
set the ID s of the units like this:
With this scheme, we have four ways to address these
Bay Cat Xs:
A complete list of all commands is given in “RS232
Control for Bay Cat X”, document 070-0120, available
from Clarity’s website:
Go to www.ClarityVisual.com
Click on LOGIN in upper right banner
Click on lower, blue
LOGIN NOW button
Main Menu
Picture
Size & Position
Aspect Ratio & Wall
Memory
Diagnostics
Advanced Options
Program Information
Advanced Options
Color Balance
Miscellaneous Options
Backlight Settings
Serial Port Settings
Auto Setup Options
Menu Options
Message in Picture
Capture Custom Logo
Serial Port Settings
Group ID 1
Unit ID 1
ASCII Response Type Symbolic
ASCII Response Terminator CR
Baud Rate 19200
Group ID Unit ID
11
12
13
14
21
22
23
24
Type of
Addresses
Affect on Bay Cat X
13
24
etc.
Only the specific Bay Cat X addressed will
obey the command. Also, the Bay Cat X
will respond to the host computer.
** All Bay Cat Xs in this RS232 loop will obey
the command
*4 Both the Bay Cat Xs whose IDs end in “4”
will obey this command
2* All five Bay Cat Xs in Group 2 will obey the
command