GE 90-30/20/Micro Universal Remote User Manual


 
GFK-0467K Chapter 4 Series 90-30/20/Micro Instructions Set 4-185
4
| _____ _____ _____
| %M0006 | | | | | |
|——| |———| BLK_|—————————|BLKMV|—————————————————|BLKMV|–
| | | | | | |
| | CLR_| | INT | | INT |
| | WORD| | | | |
|%R00100—|IN | CONST —|IN1 Q|—%R00102 CONST —|IN1 Q|— %R00109
| | LEN | +00010 | | +20000 | |
| |00035| | | | |
| |_____| CONST —|IN2 | CONST —|IN2 |
| +00005 | | +00400 | |
| | | | |
| CONST —|IN3 | CONST —|IN3 |
| +00005 | | +00000 | |
| | | | |
| CONST —|IN4 | CONST —|IN4 |
| +00400 | | +00000 | |
| | | | |
| CONST —|IN5 | CONST —|IN5 |
| +00000 | | +00000 | |
| | | | |
| CONST —|IN6 | CONST —|IN6 |
| +01500 | | +00000 | |
| | | | |
| CONST —|IN7 | CONST —|IN7 |
| +00000 |_____| +00000 |_____|
|
| _____
|ALW_ON | | %T0001
|——| |———————————————————————————————————————————| PID_|——( )——
| | IND |
| | |
| %R0001—|SP CV|– %AQ002
| | |
| | |
| %AI0003—|PV |
| | |
|%M0001 | |
|——| |———————————————————————————————————————————|MAN |
| | | |
| | %M0004 | |
| |——| |————|UP |
| | | |
| | %M0005 | |
| ——| |————|DN |
| |_____|
|
| %R00100
| _____
|
|%M0002 | |
|——| |———| ADD_|————
| | INT |
| | |
|%R00113—|I1 Q|— %R00113
| | |
| | |
| %R0002—|I2 |
| | |
| |_____|
|
| _____
|%M0003 | |
|——| |———| SUB_|—
| | INT |
| | |
|%R00113—|I1 Q|— %R00113
| | |
| %R0002—|I2 |
| | |
| |_____|