Sony SIR-3400H DVR User Manual


 
(E) 17-5
SIR-3400H / SIR-3032i / SIR-3032W
Command Contents
IDS : ID increment
Command format IDS : <1>
<1> : 0=RSV, 1=ID increment
The recording unit ID is incremented each time the IDS : 1 command is issued.
Related command : IDS?
INP : Input format setting
Command format INP : <1><2>...<17>/[ ]
<1> : Measuring unit ID number
0=Measuring unit 1 1 to 16 CH
1=Measuring unit 1 17 to 32 CH
2=Measuring unit 2 33 to 48 CH
3=Measuring unit 2 49 to 64 CH
4=Measuring unit 3 65 to 80 CH
5=Measuring unit 3 81 to 96 CH
6=Measuring unit 4 97 to 112 CH
7=Measuring unit 4 113 to 128 CH
<2> : Input format for CH1
0=DIRECT-DC coupling
1=DIRECT-AC coupling
2=IEPE
3=TEDS
<3> : Input format for CH2
<17> : Input format for CH16
Related command : INP?
MEM : Recording memo setting
Command format MEM : <1><2>...<96>/[ ]
<1><2>...<96>: ASCII characters (20h to FFhex) up to maximum 96 characters
Ex.) MEM:MEASUREMENT-1 (Annotation character string
MEASUREMENT-1 set.)
Related command : MEM?
MOD : Transport mode setting
Command format MOD : <1>/[ ]
<1> : 0=STOP, 1=FWD, 2=E-E, 3=REC, 4=FWD-PAUSE, 5=REC-PAUSE,
6=FF, 7=RSV, 8=REW, 9=RSV, A=EJECT
Ex.) MOD : 1 FWD mode
Related command : MOD?
MON : Monitor channel selection
Command format MON : <1><2>/[ ]
<1> : Measuring unit ID number <2> : Channel code
0=Measuring unit 1 1 to 16 CH 0=CH 1
1=Measuring unit 1 17 to 32 CH 1=CH 2
2=Measuring unit 2 33 to 48 CH 2=CH 3
3=Measuring unit 2 49 to 64 CH 3=CH 4
4=Measuring unit 3 65 to 80 CH 4=CH 5
5=Measuring unit 3 81 to 96 CH 5=CH 6
6=Measuring unit 4 97 to 112 CH 6=CH 7
7=Measuring unit 4 113 to 128 CH 7=CH 8
8=CH 9
9=CH 10
A=CH 11
B=CH 12
C=CH 13
D=CH 14
E=CH 15
F=CH 16
Related command : MON?
.
.
.
17. Control by Telnet