(E) 10-1
SIR-3400H / SIR-3032i / SIR-3032W
10. Network Settings (Network Screen)
This procedure is used to set the IP address and subnet mask of the recording unit.
The MAC address can be checked at this setting screen.
10-1. Setting Procedure
Opening the Network screen
1 Press the F1 key in the Measurement screen.
The Utility screen is displayed.
2 Select the “Global Setup Menu” with the f / F keys.
3 Press the F1 key to switch the screen.
4 Select the “Network” with the F1/F2 keys.
Setting
5 Use the g / G key to select the option.
Use the f / F key to select the setting value.
6 Use the F3 key to make the setting.
* The screen of “Main” – “Function” – “Display” – “Network” – “Clock” can be switched with the F1/F2 keys.
* By pressing F3 (Apply) key, the changed IP address and the changed subnet mask are set.
When escaped from the Global Setup Menu without setting, the changed value is not set.
* Press the F4 key to return to the Measurement screen.