Warning Error description Cause Countermeasures
marks
Low DC voltage The voltage of the external DC power Be sure to supply the specified external DC
supply has fallen below the prescribed voltage (11 to 30 V).
lower limit (11 V).
c
If you continue usage when this mark is displayed,
a malfunction may occur. Be sure to take the above
measures as soon as possible.
Dew condensation When the DEW function is ON, Leave the standby key at ON. The warmup
condensation occurs in the recording operation is performed. Wait until the mark no
media area if a cold recording unit is longer appears before operating.
transferred to warm places.
c
. In environment where the temperature or
humidity may change, be sure to turn ON the
condensation detection function.
. To prevent media damage due to condensation
during storage, be sure to always remove the
recording media after usage, and then set the
standby key to OFF.
. Leave a space of at least 50 mm between both
sides of the unit and any other object.
LCD message Recording unit status Remarks
60S to 00S Detecting the condensation The remaining time in detecting the
condensation is displayed
Warming Up Condensation was detected Displayed during warmup operation
600S to 000S Dissipating condensation Displays the remaining time until
condensation is dissipated
Recording/Playback
error
Recording error
The data supply to the recording media 1. If the mark is displayed frequently, the unit is
cannot catch up and the FIFO memory possibly being subjected to vibrations, jolts,
becomes full. (FIFO overflow) extreme temperatures, dust or other adverse
environmental conditions. Re-check the
installation environment.
(See section 22-1-8)
2. If the countermeasure in 1 does not fix the
problem, the recording media may be faulty.
Replace the recording media with a new one.
3. If the countermeasure in 2 does not fix the
problem, contact service engineer.
Playback error The playback data contains an error
that cannot be corrected, and re-
reading (retry) of the relevant section
was repeated. As a result, the FIFO
memory became empty, and the output
data is interrupted.
* During this retry operation, the data
remaining in the FIFO memory is
output until the correct data is read.
If the correct data is read before the
FIFO memory is emptied, playback
continues normally and the mark is
not displayed.
18. Errors and Error Messages
18-1. Warning Messages
When a malfunction occurs in the recording unit, the warning marks shown below blink in the status display
area of the LCD screen, and a buzzer will sound. Contact service engineer if the warning indicator is still
displayed after performing the measures below.