22-6 (E)
SIR-3400H / SIR-3032i / SIR-3032W
22-2-4. Power Supply System
AC (g)
Voltage (rated) : 100/120 V 220/240 V
Voltage (allowable range) : 90 to 132 V 198 to 250 V
Band (rated) : 50/60 Hz 50/60 Hz
Band (allowable range) : 47 to 66/440 Hz 47 to 66 Hz
Power consumption : 215 VA 215 VA
Standby power consumption : 50 VA 55 VA
DC ( )
Voltage (rated) : 12 V
Voltage (allowable range) : 11 to 30 V
Current consumption : 15 to 5.5 A
Battery
Nickel-metal- hydride battery: 24 V 1.1 Ah
Power supply priority : AC > DC > internal backup battery (UPS function)
22-2-5. Dimensions and Mass
Dimensions : 449 (W) x 88 (H) x 305 (D) mm (excluding projections)
Mass : Approx. 7.5 kg
22-2-6. Operating Environment
Recommended temperature/humidity for operation : 0 to 40 dC, 20 to 80 % RH (non-condensating)
(Be sure to warm up the recorder if it is operated under
5 dC.)
Recommended temperature/humidity for storage : _10 to 50 dC, 10 to 90 % RH (non-condensating)
Recommended pressure for specifications : 660 to 1060 hPa (Equivalent to the altitude of about
3000 m to _400 m)
Operating position : Horizontal (front panel facing forwards)
Vibration resistance : 14.7 m/s
2
5 Hz to 200 Hz (horizontal position)
Shock resistance : 392 m/s
2
, 11 ms (while stored)
Polution degree : II
Over voltage categoly : II
22. Specifications