Sony SIR-3400H DVR User Manual


 
18-2 (E)
SIR-3400H / SIR-3032i / SIR-3032W
18-2. Error Code
When the recording unit malfunctions during diagnostics, calibration, recording or playback operation, the
error code is displayed on the LCD screen. Take the appropriate measure based on the table below.
When using the recorder in a dusty surrounding, the data could not be played back (or verified during
recording) and also an error code is displayed. In such a case, perform a play back inside a room. If the error
code does not disappear after the appropriate measure has been taken or if the displayed error code is not
listed in this manual, contact service engineer.
-HDD- EH03 0C01 Drive 1 write retries have exceeded the designated limit
0C02 Drive 2 write retries have exceeded the designated limit
1101 Drive 1 read retries have exceeded the designated limit
1102 Drive 2 read retries have exceeded the designated limit
3001 Drive 1 format is not correct
3002 Drive 2 format is not correct
EH04 0001 Hard disk not installed in drive 1
0002 Hard disk not installed in drive 2
4401 Drive 1 is faulty
4402 Drive 2 is faulty
EH90 0001 Formatting of drive 1 failed
0002 Formatting of drive 2 failed
EH91 No TOC found
EH92 An invalid TOC was detected.
EH93 Communication error occurred on HDD board
EH95 Error occurred in peripherals
File system error
IDE controller error
StarFabric control error
PCI control error
EH96 An unknown error occurred
-ADA- EA20 00xx A/D calibration error occurred. xx is the channel.
EA30 00xx D/A calibration error occurred. xx is the channel.
EA60 ADA flash memory error
0001 CAL data was not found
0002 Unable to access
EA70 Measuring unit ID error
EA80 ADA board error
EA90 DMA timed out in REC
EA91 DMA timed out in PB
-Power Supply/ EP03 Power failure
Battery-
EP10 Battery voltage is low
-Communication- Ed50 Communication error occurred between the IF board and ADA
board
Ed60 Communication error occurred between the DSP board and ADA
board
Ed70 Communication error occurred between the IF board and DSP
Ed80 Telnet communication error
ES30 Error occurred between DPR board and DR board
ES40 Error occurred between DPR board and IF board
ES50 Error occurred between DR board and IF board
-Synchronizing- EX30 Sync Setting error/cable error
EX31 Sync No target/sync playback data
EX32 Sync Recording/playback error
EX33 Sync target is recording alone
18. Errors and Error Messages