O: Setting enabled The reference section for common Telnet functions is section 17-2, and so this reference was omitted except for independent functions.
Setting Default setting Operation Remarks
Reference
LCD screen
Key Telnet Panel
section
Fan control Off O
For acoustic measurement and other
7-2-1
situations where silence is needed
Condensation sensor Off O
Based on changes in the operating environment
7-2-2
Synchronization mode Master O
Based on changes in the operating environment
7-2-3
Frequency type 48 kHz series O Fixed at 48 kHz series 8-2-1
Auto repeat Off OOFor setting at hard disk empty states 8-2-2
Overwrite Off O 8-2-3
Trigger mode Single OO
For starting recording with an external signal
8-2-4
Pre-trigger recording Off O For recording signals before the trigger 8-2-5
IRIG-B timecode On O For using IRIG input 8-2-6
Response characteristics Realtime OO 9-2-1
of the peak indicator
Bar meter scale % OO
For switching the bar meter indicator
9-2-2
LCD contrast 5 O For adjusting the screen 9-2-3
LCD brightness 5 O For adjusting the screen 9-2-4
Recording unit network O 10-1
Setting the recording unit clock
OOBefore recording 11-1
ID number OO For adding IDs during recording 12-1
INDEX number O
For adding INDEX during recording
12-2
Recording/Playback speed 1 (Normal) OO For changing the speed 12-3
Number of recording channels
32 ch O 12-4
Transmission format S
(Single-ended)
O (Front)
For the IEPE input, set to the single 12-8
ended input.
Recording memo OO If needed during recording 12-9
Test signal OO For recording test signals 12-11
Mark OO If needed during recording 12-12
Changing to the address,
O 13-1
amount of recording media
remaining, or time display
Clearing the peak On OO 13-2
indicator and over indicator
Changing the speaker Voice O When the speaker or earphone playback 13-3
output annotations signal source is switched
Adjusting the playback volume
O (Front)
Based on the operating environment
13-4
Changing the AC voltage 100/120 V or
O (Rear)
13-5
200/240 V
Save of setting values/ O
For making batch settings with the default 14-1
Recall of setting values settings or with recording settings with a
current address
6. Setting and Check Items
6-1. Default Settings
c
Items described here as check items can only be checked.
6-1-1. Recording Unit Setting/Checking (Including Media Settings)