Sony SIR-3400H DVR User Manual


 
(E) 17-9
SIR-3400H / SIR-3032i / SIR-3032W
Status Commands
Status commands are used to request status information from the recording unit. When the recording unit
receives a status command, it sends the corresponding status information.
n
The /[ ] parameter specifies any one ID number, and can be omitted when only one recording unit is connected
or when the target is the recording unit with ID=0. When performing synchronous operation, the master is
ID=0 and the subordinate is ID=1.
Command Contents
ADR? Recording media ADDRESS
Command format ADR?/[ ]
Returned format ADR : <1><2>...<14>
Recording media ADDRESS
<1><2><3> : hhh (hour)
<4><5> : mm (minutes)
<6><7> : ss (seconds)
Remain
<8><9><10>: hhh (hour)
<11><12> : mm (minutes)
<13><14> : ss (seconds)
Ex.) ADR? (current recording media ADDRESS requested)
ADR?/1 (current recording media ADDRESS for recording unit with ID=1
requested)
ALM? Alarm status
Command format ALM?/[ ]
Returned format ALM : <1><2><3><4>
<1> : 0=Normal, 1=Power supply voltage drop
<2> : 0=Normal, 1=Condensation
<3> : 0=Normal, 1=Recording/playback error (buffer over/underflow)
<4> : 0 (other)
AUX? Front panel status
Command format AUX?/[ ]
Returned format AUX : <1><2><3>
Status of AUX1 0=RSV
Status of AUX2 0=OFF 1=ON
Status of EXT TC 0=OFF 1=ON
Ex.) AUX : 100 AUX1=ON
AUX : 010 AUX2=ON
AUX : 001 EXT TC=ON
BAR? Bar meter setting readout
Command format BAR?/[ ]
Returned format BAR : <1><2>
<1> : 0=Real-time, 1=Peak hold
<2> : 0=Unidirectional, 1=Bidirectional
Related command : BAR
CAC? Calibration protect status
Command format CAC?/[ ]
Returned format CAC: <1>
<1> : 0=The measuring unit can be calibrated.
1=The calibration of the measuring unit is inhibited.
CAL? Calibration status
Command format CAL?/[ ]
Returned format CAL : <1>
<1> : 0=Calibration finished normally
1=Calibration finished abnormally
2 to 7=Value other than 01
Related command : CAL