VT1422A Command Reference 283Chapter 7
DIAGnostic
DIAGnostic:IEEE?
DIAGnostic:IEEE? returns the currently set IEEE mode.
Comments • The data type is int16.
• Related Commands: DIAG:IEEE
• *RST Condition: DIAG:IEEE 1
• Send with VXIplug&play Function: hpe1422_cmdInt16_Q(...)
DIAGnostic:INTerrupt[:LINe]
DIAGnostic:INTerrupt[:LINe] <intr_line> sets the VXIbus interrupt line the
module will use.
Parameters
Comments • Related Commands: DIAG:INT:LINE?
• Power-on and *RST Condition: DIAG:INT:LINE 1
• Send with VXIplug&play Function: hpe1422_cmd(...)
Usage DIAG:INT:LINE 5
Module will interrupt on interrupt line 5
DIAGnostic:INTerrupt[:LINe]?
DIAGnostic:INTerrupt[:LINe]? returns the VXIbus interrupt line that the module is
set to use.
Comments • Returned Value: Numeric 0 through 7. The data type is int16.
• Related Commands: DIAG:INT:LINE
• Send with VXIplug&play Function: hpe1422_cmdInt16_Q(...)
Usage DIAG:INT?
Enter statement will return 0 through 7
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
intr_line numeric (int16) 0 through 7 none