GE GFK-0804B Universal Remote User Manual


 
E
E-3GFK-0804B Appendix E Data Acquisition, Logging, and Display Program
Ability to download register data such as recipes to a Micro PLC. Comments can be
used in the file, as in the following example, to describe the data being downloaded. In
this example, data is sent to registers R100, R101, R102, and R103. To the application
program in the Micro PLC, these registers represent paint color, number of widgets,
starting serial number, and oven temperature.
Finally, a Manual mode is available which allows you to poll a Micro PLC, and
observe both the transmitted data (including header and checksum information)
and the received data. This is valuable when you are trying to determine that the
Micro PLC is actually sending the appropriate register or I/O data.
In Manual mode, you can also send data to the Micro PLC’s register or I/O tables as
individual words, and to the register table as a bank of up to 30 (typical) registers.