Mitsubishi Electronics AJ65bt-r2 Home Theater Server User Manual


 
7 - 23
MELSEC-
A
7 USING FRAMES WHEN EXCHANGING DATA
7.5.1 List of default registration frames
The default registration frames are frames preregistered in the R2.
The No. of the default registration frame and the contents of the data during
transmission/reception are shown below.
Default registration
frame No.
Hexadecimal Decimal
No. of
registered
bytes
Frame contents during
transmission/reception
Remarks
0H 0 Use prohibited
1H to FEH
1 to
254
1
Same data (1 to FE
H) as registration frame
No.
For example, registration No. 2 is data
STX(02).
FFH 255 Use prohibited
100H 256 1 NUL (00H)
101H 257 2 FFH (1 byte)
The actually registered value is the special
character FF
H and FFH.
102H 258 2 CR (0DH), LF (0AH)
103H 259 2 DLE, STX
104H 260 2 DLE, ETX
105H 261 2 00H, FEH
106H 262 3 00H, 00H, FEH
107H 263 3 ETX, sum check (FFF1H)
108H 264 5 ETX, sum check (FFF1H), CR, LF
109H to
12BH
265 to
299
Use prohibited
12CH 300 4 STX, ‘0’, ‘0’, ‘G’ Head frame for in-zone ON command
12DH 301 5 STX, ‘0’, ‘0’, ‘S’, ETX In-zone OFF command
12EH 302 4 STX, ‘0’, ‘0’, ‘D’ Head frame of barcode data
12FH 303 4 STX, ‘0’, ‘0’, ‘E’
2600 Series
(DENSEILAMBDA)
Head frame at barcode reader error
130H 304 4 STX, ‘B’, ‘R’, ETX Frame at no-read
131H 305 3 STX, ‘E’, ‘R’ Head frame at error
132H 306 4 ESC, ‘A’, ‘0’, CR Synchronous ON command
133H 307 4 ESC, ‘A’, ‘0’, ‘,’
Head frame of synchronous ON command
at edge input
134H 308 4 ESC, ‘A’, ‘1’, CR
TLMS-3500RV
(TOHKEN)
TOHKEN synchronous OFF command
135H 309 4 STX, CAN, CR, LF Frame at no-read
136H 310 4 STX, BEL, CR, LF
DS50AF
(IDEC DATALOGIC)
Frame at error
137H 311 2 ’, CR End frame
138H 312 2 ‘RD’
139H 313 2 ‘WT’
13AH 314 2 ‘AR’
13BH 315 2 ‘AW’
13CH 316 2 ‘PR’
13DH 317 2 ‘PW’
13EH 318 2 ‘TS’
V620
(OMRON)
Head frame of various commands