Mitsubishi Electronics AJ65bt-r2 Home Theater Server User Manual


 
9 - 25
MELSEC-
A
9 PROGRAM EXAMPLES
(f) Station No. 3 program
R2 initialization (initial data read)
Set initial data read
request
Reset initial data read
request
Complete initialization
R2 initialization (initialization data write)
Change to bank 2
Set R2 transmission area
size to 100
H
Set R2 reception area
head address to 300
H
Set R2 transmission area
size to 100
H
Set transmission area 2)
transmission size to 100
H
Set transmission area 2)
M station head address
to 1C0
H
Set reception area trans-
mission size to 100
H
Set R2 reception area
head address to 300
H
Set reception area M
station head address
to 2C0
H
Set EEPROM function area
transmission size to 0
Set user registration frame
area transmission size to 0
Set monitor transmission
area 1) transmission size
to 0
Set monitor transmission
area 2) transmission size
to 0
Set reception timeout time
to 2 sec.
Set transmission timeout
time to 2 sec.
Change to bank 0
Set initialization data write
complete flag
R2 initialization (initialization execution)