This projector is equipped with a lamp to project images. This lamp is a consumable. It may burn out or its brightness may
decrease during use. In such cases, replace the lamp with a new one as soon as possible. Be sure to replace the lamp with a
new lamp sold separately that is exclusive to this projector. Contact your dealer for purchase of the lamp.
Spare lamp VLT-HC9000LP
Warning:
• Be careful not to drop the lamp xing screws inside of the projector. Don’t put a metal piece or ammable object
into the projector. Using the projector with any foreign object present inside may result in electric shock or re.
When you can’t remove the foreign object from the inside, contact your dealer for removal.
• Be sure to install the lamp securely. When the lamp isn’t installed properly, it won’t illuminate. Improper installation
may also result in re.
• Don’t shake the removed lamp or don’t lift it above your face. Your eyes may be injured by ying or falling glass
fragments.
• Don’t replace the lamp immediately after use because the lamp cover will be very hot. You may get burned. Turn o the
power using the POWER button. After the lamp goes out, wait about 1 minute until the intake and exhaust fans for cooling
the lamp stop rotating. Then turn o the main power switch, unplug the power cord, and wait at least 1 hour to allow the
lamp to cool down enough to the touch.
• Do not touch the lamp directly. It may break and cause injury or burn.
Interval of lamp replacement
The recommended interval of lamp replacement is about 4000 hours*
1
*
2
of consecutive use. Such interval diers depending
on the operating environment and may be shorter than 4000 hours*
1
*
2
. When the lamp operation time exceeds 3800
hours*
1
*
2
, the indicator will change color become to lit orange only to warning the lamp life will be excess, and the lamp
replacement message (LAMP replacement) will appear on the screen. When the user press MENU button, the lamp
replacement message will disappear but the indicator light still keep stay in the orange until the Lamp Time Reset is reset. (See
page 45)
*1: Duration when Lamp Mode of the Setup menu is set to Normal. When it is set to High, this duration will be shorted.
*2: When Lamp Mode is set to High, this duration will be shorted to 2000 hours.
Caution:
• Don’t remove the lamp for any purpose other than replacement. Unnecessary removal of the lamp may result in a
breakdown.
• This projector uses a high-pressure mercury lamp as the light source. The high-pressure mercury lamp may
explode or fail to illuminate permanently because of an impact, scratch, or deterioration through use. The period
of time until explosion or permanent failure to illuminate varies considerably from lamp to lamp, depending on
operation conditions. Therefore, the lamp may explode soon after the start of use.
• The possibility of explosion of the lamp increases if you use it beyond its replacement period. When the instruction
of lamp replacement appears, replace it with a new one immediately even if the lamp is still lighting normally.
• When the high-pressure mercury lamp explodes, glass fragments will scatter inside or outside the lamp box and
the gas charged inside the lamp will diuse inside or outside the projector. The gas inside the lamp contains
mercury. Be careful not to breathe it or avoid it from entering your eye or mouth. If you should breathe it or if it
should enter your eye or mouth, see a doctor immediately.
• In the event that the high-pressure mercury lamp exploded, glass fragments may have been scattered inside the
projector. Ask your dealer to replace the lamp and to inspect the inside of the projector. When you clean or replace
the lamp by yourself, be sure to hold the handle of the lamp. You may get injured by glass fragments.
• When removing the lamp from the ceiling-mounted projector, use the lamp replacement tray packed with the
projector or option lamp to prevent glass fragments from scattering.
• Be sure to use the lamp exclusive to this projector, VLT-HC9000LP. Use of other lamps may cause a failure of the projector.
Replacing the lamp