Mitsubishi Electronics HC9000DW Home Theater Screen User Manual


 
EN-52
POWER indicator STATUS indicator
Indicators
This projector has two indicators, each of which shows the operation condition of the projector.
The following oer solutions to possible problems. If these problem persist, turn the projector o and consult your
dealer.
Normal condition
POWER
STATUS CONDITION NOTE
Steady
red
O
Standby
Lamp standby for power-o The power cannot be turned on by pressing the
POWER button.
Blinking
red
Steady
green
Blinking
green
Lamp standby for power-on
The power cannot be turned o by pressing
the POWER button.
Steady
green
The power is on. (Normal condition)
Abnormal condition
POWER
STATUS
CONDITION POSSIBLE SOLUTION
Steady red
Blinking orange
Electronic boards error1
Unplug the power cord, and then contact your
dealer .
Steady
red
Blinking orange
and red
Electronic boards error2
Unplug the power cord, and then contact your
dealer .
Steady
red
Blinking
red
Electronic boards error3
Unplug the power cord, and then contact your
dealer .
Steady
red
Blinking orange
and green
The lamp cover isn’t closed.
Abnormal temperature
• The ventilation grilles are clogged with dust or dirt.
• The room temperature is high.
Close the cover correctly.
• Clean the ventilation grilles.
• Relocate the projector to a cooler place.
Steady red
Blinking
green
Fans error
Power board error
Turn o the power switch and then turn it back
on again.
If the above solution is not eective, contact
with your dealer.