203 PARALLEL
RUNNING
[disable]
enable
Selects whether two or more VTRs can be operated
synchronized.
disable: Synchronized operation is not carried out.
enable: Synchronized operation is enabled.
Note
For synchronized operation to be possible, this item must
be set to “enable” on all of the connected VTRs.
204 VIDEO REMOTE
CONTROL SELECT
Make settings for control from HKDV-900/503 via the
VIDEO CONTROL (15P) connector.
Sub item
1IMAGE
ENHANCER
U&D
UP
[DOWN]
Select whether to control the up-converter or down-
converter whether controlling the image enhancer.
U&D: Control both the up-converter and down-converter.
UP: Control the up-converter.
DOWN: Control the down-converter.
2 D2 SETUP BLACK
[SETUP]
Select the menu item to be controlled by the SETUP dial on
the HKDV-900/503 with the D2 button pressed.
BLACK: Control menu item 743.
SETUP: Control menu item 762.
For details, see items 743 and 762.
Note
After changing the setting for this item, power off this unit or
HKDV-900/503 and power it on again.
205 REMOTE
NETWORK
on
[off]
Specifies whether or not control from a network is possible.
on: Allows control from a network.
off: Does not allow remote control from a network.
Item number Item Setting Function
301 EDIT OPERATION
MODE
CG
[normal]
Selects the animation edit mode. For normal editing, use
the “normal” setting.
CG: Primarily for recording computer graphics, this setting
allows editing by individual frames. When the edit is
completed, the OUT point automatically becomes the
next IN point. The next OUT point is automatically set
one frame ahead of the IN point.
normal: Use this setting for normal editing.
302 PREROLL TIME 0 sec
[5 sec]
30 sec
This sets the preroll time. The range is from 0 to 30
seconds, in steps of 1 second. The preroll time should
generally be set to at least 3 seconds, and for phase
adjustment with an editing controller it is recommended to
set the preroll time to at least 5 seconds.
303 POSTROLL TIME 0 sec
[5 sec]
30 sec
This sets the tape running time after passing the OUT point
(postroll time) in automatic editing.
The range is from 0 to 30 seconds, in steps of 1 second.
Item number Item Setting Function