Environmental specifications for the S8500 Media Servers are shown in Table 3.
Table 3: S8500 Media Server environmental specifications
Parameter S8500B Specifications S8500C Specifications
Acoustical
Noise
Emissions
Sound power, idling: 65 decibel maximum
Sound power, operating: 65 decibel
maximum
Same as S8500B
Same as S8500B
Environment:
Air
Temperature
Media server on:
50.0°F to 95.0°F (10°C to 35°C)
Altitude: 0 ft to 2999 ft (0 m to 914 m)
Media server off:
-40°F to 140°F (-40° to 60° C)
Maximum altitude: 6998 ft (2133 m)
Same as S8500B
Same as S8500B
Same as S8500B
Same as S8500B
Environment:
Humidity
Media Server on: 8% to 80%
Media Server off: 8% to 80%
Same as S8500B
Same as S8500B
Heat Output
Minimum configuration: 297 BTU (87 W)
Maximum configuration: 512
BTU (150 W)
Minimum configuration: 341
BTU (100 W)
Maximum configuration: 1024
BTU (300 W)
Electrical
Input
Receptacle U.S.: NEMA 5-15 A
Circuit Breaker: 15 A
Sine-wave input (47 Hz to 63 Hz) required
Input voltage low range: 100 – 127 VAC
Input voltage high range: 200 – 240 VAC
Input kilovolt-amperes (approximate):
0.09 – 0.15 kVA
Amp draw:
100 to 127 V ~ 4.6 A
200 to 240 V ~ 2.3 A
Same as S8500B
Same as S8500B
Same as S8500B
Same as S8500B
Same as S8500B
Input kilovolt-amperes (approximate):
0.10 – 0.55 kVA
Amp draw:
100 to 127 V ~ 6.0 A
200 to 240 V ~ 3.0A