Avaya S8500 Home Theater Server User Manual


 
Chapter 2: SNMP Configuration
28 Installing and Configuring the Avaya S8500 Media Server February 2007
Default IP addresses for the UPS
The following table shows the default IP addresses for the UPS.
For how to administer the SNMP module in the UPS, see Administering the SNMP module
on
page 29.
Prerequisites for configuring the SNMP module
Before you configure the SNMP module, you must complete the following prerequisites:
Your Services laptop computer is plugged into the correct administration port on the SNMP
module.
The UPS is plugged into a nonswitched electrical outlet.
The communication protocol on your computer has the following port settings so that you
can use your terminal emulation program:
-
9600 baud
-
No parity
-
8 data bits
-
1 stop bit
-
No flow control
Note:
Note: Avaya Terminal Emulation and HyperTerminal are supported terminal emulation
applications.
If a Network Management System (NMS) is to monitor the UPS, you coordinated the
assignment of community names with the network administrator. If an NMS is not used,
you set the community names to unique string values.
IP address for the UPS 198.152.254.239
Subnet mask for the UPS 255.255.255.0
Gateway address for the UPS 198.152.254.201
IP address for the
trap receiver (media server)
Customer provided