B. Specifications
B.4 Ballast values for a base stand OLite display
All calculations are based upon a wind load of 0,8 kN/m² (±129 km/h) which comply with the TUV regulations.
For more information consult the “Ballast calculator” tool, available on Barco’s web site.
The ballast values are given per OLite rental foot mounted upon two foot beams. Ballast must be placed upon
the last 30 cm of the foot beams.
Minimum ballast values for an OLite display installed at the front of the foot beams
Lb
Ballast
1
2
3
...
n
0,3 m
Image B-1
Single OLite rental foot
Height
Tiles
1,2 meter foot beams (Lb)
Minimum ballast (kg)
2,4 meter foot beams (Lb)
Minimum ballast (kg)
4 meter foot beams (Lb)
Minimum ballast (kg)
1 632917
2 150 70 41
3 266 124 73
4 423 197 115
5
620 289 169
6 857 400 234
7
1134 529 309
8 1451 677 396
9 1809 844 493
10 Not allowed Not allowed Not allowed
11 Not allowed Not allowed Not allowed
12 Not allowed Not allowed Not allowed
R5976832 OLITE RENTAL DISPLAY 29/05/2007