Barco r5976832/07 Projection Television User Manual


 
12. Servicing
12.4 Replacement of an OLite module on-site
This procedure is illustrated with OLite 510 modules. Nevertheless, the same procedure is valid for OLite 612
modules as well.
WARNING: Always use this procedure on OLite modules which are mounted in the display. The use of a
module safety cable is compulsory.
WARNING: ALWAYS disconnect the power cord from the OLite control box before connecting or disconnect-
ing the module cable string or one of the OLite modules.
CAUTION: Handle the OLite 510 modules with care. Note that the foil, covering the LED’s, is made of thin
polycarbonate. This foil ensures that the OLite 510 module has an IP65 protection rating.
Necessary tools
OLite module safety cable (R9853390).
How to replace an OLite module in a display with back access ?
1. Read and head the servicing safety instructions.
2. Disconnect the power cord from the OLite control box which drives the OLite module you want
to replace.
3. Disconnect the OLite module from the cable string by unscrewing the captive lock of the plug and then pull out the plug.
Image 12-5
4. Attach a module safety cable with the electrically disconnected OLite module as illustrated.
90
R5976832 OLITE RENTAL DISPLAY 29/05/2007