Barco r5976832/07 Projection Television User Manual


 
12. Servicing
12.2 OLite module diagnostic
Status LED’s OLite module
The OLite module is provided with two status LED’s. One green and one red LED. The two status LED’s are located just below the
external fan. The red LED indicates the status of the software and the microprocessor. The green LED indicates the status of the
incoming data and sync.
GR
Image 12-1
Location of status LED’s on the OLite module.
R Red colored status LED.
G Green colored status LED.
Diagnostic
Red LED
Green LED
Diagnostic Action
OFF OFF OLite module has no power Check connections with cable string.
Flashing
(40 ms)
OFF Software of the OLite module is
corrupt .
Replace OLite module.
Flashing
(500 ms)
OFF (or ON) OLite module receives no data. Check status of OLite modules connected with the same
cable string.
Different status: replace OLite module.
Same status: set the control box in internal mode
(see manual control software). If the status of all
modules remains the same, replace the control box.
If only the status of this module remains the same,
replace this OLite module.
Flashing
(500 ms)
Flashing
(160 ms)
OLite module functions normally.
R5976832 OLITE RENTAL DISPLAY 29/05/2007 87