4. Components of an OLite rental tile
In a standard OLite rental tile the power/data output ports number 5 and 6 are not used but sealed with a cover
(Z3499467). Four strings of OLite modules are sufficient to fill the grid of an OLite rental frame.
Using an OLite control box as stand alone re-sync unit
The OLite control box acts like a stand alone re-sync unit in case no power is applied to the power input socket of the control box.
When you use the OLite control box as stand alone re-sync unit ensure to place dummy plugs upon the power input and output
sockets. Maximum connect three (3) stand alone re-sync units in series. The cable length used between two control boxes may not
exceed 5 meter.
Power cables used between OLite control boxes
To meet the demands of each OLite application Barco offers several lengths of powercables to link power from control box to control
box. Note that the power output port of the last OLite control box in the power chain has to be sealed with a dummy power p
lug.
Image 4-14
Power link cable of 0,8 meter (R9851760).
Image 4-15
Power link cable of 1,5 meters (R9850241).
Image 4-16
Power link cable of 4,5 meters (R9850150).
Image 4-17
Power link cable of 9 meters (R9850260).
Image 4-18
Dummy power plug (R9850280).
Data cables used between OLite control boxes
To meet the demands of each OLite application Barco offers several lengths of data cables to link data from control box to control
box. Note that the data output port of the last OLite control box in the data chain has to be sealed with a dummy data plug.