Barco r5976832/07 Projection Television User Manual


 
9. OLite creativity pack
9.3 Possibilities
Control box possibilities
All six (6) output ports of the control box are activated.
Up to 16 OLite 510 modules per output port.
Up to 64 OLite 510 modules per control box (due to power limitations).
Up to 12 OLite 612 modules per output port.
Up to 48 OLite 612 modules per control box (due to power limitations).
CAUTION: The digitizer can only drive one type of OLite modules at the same time. So, use either all OLite 510
or all OLite 612 modules on the same digitizer.
WARNING: ALWAYS disconnect the power cord from the OLite control box before connecting or disconnect-
ing the module cable string or one of the OLite modules.
The following OLite possibilities are illustrated with OLite 510 modules. Nevertheless, the same possibilities
are valid for the OLite 612 modules as well, but with the limitation of maximum 12 OLite 612 modules per
output port and maximum 48 OLite 612 modules per control box.
Module angle possibilities
The OLite modules can be placed either horizontally (0° or 180°) or vertically (90° or 270°). However for outdoor use it’s rec-
ommended to install the modules horizontally with the shaders up (0°). Angle placement is no
t allowed.
0° / 180° 90° / 270°
Image 9-8
Module to module cable string possibilities
The cable string (A) has four plugs to connect a module (B) to. The maximum module spacing between two neighboring plugs
is 40 centimeter (center to center), either horizontally or
vertically.
400 mm
A
B
C
Image 9-9
70 R5976832 OLITE RENTAL DISPLAY 29/05/2007