Intel ZT 7102 TV Video Accessories User Manual


 
Intel
®
NetStructure
TM
ZT 7102 Chassis Management Module
RPC
Technical Product Specification 109
Note: Error codes 100 and 101 will never be returned by the CMM when using RPC. If you receive these
error codes, they are most likely being returned by the RPC client. Consult your RPC client
documentation or code to find the description of these errors.
20.2.3 ChassisManagementApi() Threshold Response Format
The following table documents the format of ChassisManagementApi() queries that return data of
type DATA_TYPE_ALL_THRESHOLDS.
100 E_SNMP_CMD_UNSUPPORTED Internal CMM Error
101 E_SNMP_ERROR Internal CMM Error
102 E_SNSR_VALUE_OUT_OF_RANGE Internal CMM Error
103 E_SNSR_AUTH_ERROR Internal CMM Error
104 E_WP_INITIALIZE_LIBS Internal CMM Error
105 E_WP_CFG_READ_ERROR CMM config file may be corrupted
106 E_WP_CFG_WRITE_ERROR CMM config file may be corrupted
107
E_WP_THRESHOLD_UNSUPPORTED
The sensor being queried doesn't support a
particular threshold.
108
E_WP_INVALID_TARGET
The sensor doesn't support a "current”
value. This happens when querying a
current value on a discrete sensor type.
109 E_WP_INVALID_LOCATION Not a valid -l location
110 E_WP_INVALID_DATA_ITEM Not a valid -d parameter
111 E_WP_INVALID_SET_DATA Not a valid -v parameter
112 E_WP_CMD_UNSUPPORTED Not a supported command
113
E_WP_STANDBY_CMM
Can't execute this command on the
standby CMM.
114 E_WP_I2C_ERROR Internal CMM Error
115 E_FT_SEM_GET_FAILURE Internal CMM Error
116 E_DRONE_NOT_FOUND Internal CMM Error
117 E_INTERNAL_ERROR Internal CMM Error
118 E_BPM_PWR_SUPPLY_NOT_PRESENT Power Supply Not Present Error
119 E_NEM_INTERNAL_FAILURE Internal CMM Error
120 E_WP_CMM_RESET Internal CMM Error
121 E_UPDATE_INPROGRESS Update in Progress
122 E_MSGQ_START Initilization message
Table 45. Error and Return Codes for the RPC Interface (Sheet 4 of 4)
Code #: Error Code String Error Code Description