Intel ZT 7102 TV Video Accessories User Manual


 
Intel
®
NetStructure
TM
ZT 7102 Chassis Management Module
Health Event Strings
Technical Product Specification 71
11.4.1 All Locations
Note: For Threshold-based sensor events, strings for SEL entries are the same except they begin with the
word “Crossed” (i.e., “Crossed Upper critical going high asserted")
11.4.2 PowerSupplyN Location (IPMI-Compliant Supplies Only)
Note: “Power Supply feed lost” event string is currently not implemented.
Table 29. Threshold-Based Sensor Event Strings (Voltage, Temp, Current, Fan)
Event String Event Code Event Severity
"Lower non-critical going low asserted " 16 Minor
"Lower non-critical going high asserted " 17 Minor
"Lower critical going low asserted" 18 Major
"Lower critical going high asserted" 19 Major
"Lower non-recoverable going low asserted" 20 Critical
"Lower non-recoverable going high asserted" 21 Critical
“Upper non-critical going low asserted" 22 Minor
“Upper non-critical going high asserted" 23 Minor
"Upper critical going low asserted" 24 Major
"Upper critical going high asserted" 25 Major
"Upper non-recoverable going low asserted" 26 Critical
"Upper non-recoverable going high asserted" 27 Critical
"Lower non-critical going low deasserted " 28 OK
"Lower non-critical going high deasserted " 29 OK
"Lower critical going low deasserted" 30 OK
"Lower critical going high deasserted" 31 OK
"Lower non-recoverable going low deasserted" 32 OK
"Lower non-recoverable going high deasserted" 33 OK
"Upper non-critical going low deasserted" 34 OK
"Upper non-critical going high deasserted" 35 OK
"Upper critical going low deasserted" 36 OK
"Upper critical going high deasserted" 37 OK
"Upper non-recoverable going low deasserted" 38 OK
"Upper non-recoverable going high deasserted" 39 OK
Table 30. Power Supply Event Strings (PowerSupplyN)
Event String Event Code Event severity
"Power Supply feed lost" 51 Critical
“Power Supply feed lost or out of range” 52 Critical
"Recovered from error conditions" 48 OK