Obtaining FRU Information
90 Technical Product Specification
16.3 Chassis FRU Validity Check
Chassis FRU validity is read on a periodic basis (every 24 hrs). A reuse/redefinition of two
existing BIST FRU error messages in place when one or both of the Chassis FRU cannot be read.
When the FRU (usually primary) cannot be read, and another message for when both primary and
secondary cannot be read
"Primary FRU unreadable - using Secondary"
"FRU unreadable!"
These two error messages are now used if the chassis FRU is detected to be corrupt will be a SEL
entry and an error message will go into /home/log/error.log
productserialnumber Lists the serial number field in the FRU product area for the location
productrevision Lists the revision field in the FRU product area for the location
chassisall Lists all chassis area FRU information for the location
chassispartnumber Lists the part number field in the FRU chassis area for the location
chassisserialnumber Lists the serial number field in the FRU chassis area for the location
chassislocation Lists the location field in the FRU chassis area for the location
chassistype Lists the type field in the FRU chassis area for the location
listdataitems Displays a list of all of the FRU dataitems that can be queried for the FRU target
Table 41. Dataitems Used With FRU Target (-t) to Obtain FRU Information (Sheet 2 of 2)
Data Item Description