Technical Product Specification 111
healthevents
List of human-readable health events. Lines
are separated by line feeds with a
null-terminator at the end.
"(null)” or "" if there are no healthevents
Refer to Section 11.0, “Health Event Strings”
on page 67
Syntax:
[Critical/Major/Minor] Event: [Health String]
/n /0
Major Event: Fan Tray 3 Pres Fan
Tray Removed
Major Event: FANTK9 Lower critical
going low asserted
Major Event: FANTK8 Lower critical
going low asserted
Major Event: FANTK7 Lower critical
going low asserted
Minor Event: BP +12V Upper
non-critical going high asserted
ListDataItems
List of available dataitems. Lines are
separated by line feeds and a null-terminator
at the end.
Syntax:
[Dataitem] /n /0
presence
listtargets
listdataitems
health
healthevents
sel
snmpenable
snmptrapcommunity
snmptrapaddress1
snmptrapaddress2
snmptrapaddress3
snmptrapaddress4
snmptrapaddress5
redundancy
powerstate
ListTargets
List of available targets. Targets represent
the sensor data records (SDRs) for a
particular component. Lines are separated
by line feeds with a null-terminator at the
end.
Syntax:
[Sensor Name] /n /0
Brd Temp
+1.5 V
+2.5 V
+3.3 V
+5 V
location
Null-terminated string containing the
user-specified physical location of the CMM,
16 characters maximum.
Syntax:
[Location String] /0
Server room 3
powerstate
Human readable powerstate information
containing the target blade powerstate
information. Lines are separated by line
feeds with a null-terminator at the end.
Syntax:
Board is [present or not present] /n
Board HEALTHY# signal is [asserted or not
asserted /n
Board has [not] been powered up by the
CMM /n
Board is in [active or offline] mode. /n /0
Board is present
Board HEALTHY# signal is asserted
Board has been powered up by the
CMM
Board is in active mode.
Table 47. String Response Formats (Sheet 2 of 4)
Dataitem Return format Example