Intel ZT 7102 TV Video Accessories User Manual


 
Intel
®
NetStructure
TM
ZT 7102 Chassis Management Module
Example CLI Commands
140 Technical Product Specification
Get a blade’s FRU
information
cmmget –l blade[1-19] –d fru A list of FRU information.
Find out what sensors
are on blade 3.
cmmget –l blade3 –d listtargets
A list of sensor names as defined in
their SDRs on blade 3.
List the data items that
can be queried or set
on blade 4.
cmmget –l blade4 –d listdataitems A list of dataitems for blade 4.
Find out what can be
queried on blade4’s
+3. 3V sensor.
cmmget –l blade4 –t “+3.3V –d listdataitems
A list of commands to be used as
dataitems for the +3.3V.
Enable SNMP Traps cmmset –l cmm –d snmpenable –v enable Success or failure
Set SNMP Trap
Address1
cmmset –l cmm –d snmptrapaddress1 –v
134.134.100.34
Success or failure
Set SNMP
Community
cmmset –l cmm –d snmpcommunity –v public Success or failure
Table 55. Example CLI Commands (Sheet 2 of 2)
Use Case CLI Command Return