Intel ZT 7102 TV Video Accessories User Manual


 
Intel
®
NetStructure
TM
ZT 7102 Chassis Management Module
RPC
118 Technical Product Specification
Enable the
SNMP Traps.
pszCMMHost: localhost
uCmdCode: CMD_SET
pszLocation: chassis
pszDataItem: SNMPEnable
pszSetData: enable
uReturnType: not used
ppvbuffer: not used
The return code from ChassisManagementApi()
indicates success or failure.
Set the SNMP
Target.
pszCMMHost: localhost
uCmdCode: CMD_SET
pszLocation: chassis
pszDataItem: SNMPTrapAddress[1-5]
pszSetData: 134.134.100.34
uReturnType: not used
ppvbuffer: not used
The return code from ChassisManagementApi()
indicates success or failure.
Set the SNMP
Community.
pszCMMHost: localhost
uCmdCode: CMD_SET
pszLocation: chassis
pszDataItem: SNMPCommunity
pszSetData: public
uReturnType: not used
ppvbuffer: not used
The return code from ChassisManagementApi()
indicates success or failure.
Set the Telco
Alarm on.
pszCMMHost: localhost
uCmdCode: CMD_SET
pszLocation: CMM
pszDataItem: TelcoAlarm
pszSetData: 1
uReturnType: not used
ppvbuffer: not used
The return code from ChassisManagementApi()
indicates success or failure.
Light Major
LED on the
CMM.
pszCMMHost: localhost
uCmdCode: CMD_SET
pszLocation: CMM
pszDataItem: MajorLED
pszSetData: 1
uReturnType: not used
ppvbuffer: not used
The return code from ChassisManagementApi()
indicates success or failure.
Table 50. RPC Usage Examples (Sheet 3 of 3)
Example
ChassisManagementApi() [in]
parameters