CHAPTER 3 SPECIFICATIONS
3
3.2 Performance Specifications
3.2.1 Number of parameters that can be set
*1 The value can be configured in intelligent function module switch setting.
*2 The counting speed is affected by the pulse rise/fall time.
The number of pulses that can be counted depending on the counting speed is as follows. Note that the count may be
incorrect when pulses with long rise/fall time are counted.
3.2.1 Number of parameters that can be set
Configure the parameters of the initial setting and the auto refresh of the high-speed counter module within the number
of parameters that can be set to the CPU module or head module, including the number of parameters set for other
intelligent function modules. For the number of parameters that can be set to the CPU module and head module, refer
to the following.
MELSEC-L CPU Module User's Manual (Hardware Design, Maintenance and Inspection)
MELSEC-L CC-Link IE Field Network Head Module User's Manual
(1) Number of high-speed counter module parameters
The following number of parameters can be set for one high-speed counter module.
Counting speed switch
setting
500k 200k 100k 10k
Rise/fall time Both 1- and 2-phase inputs
t = 0.5s or less 500kPPS 200kPPS 100kPPS 10kPPS
t = 1.25s or less 200kPPS 200kPPS 100kPPS 10kPPS
t = 2.5s or less 100kPPS 100kPPS 10kPPS
t = 25s or less 10kPPS 10kPPS
t = 500s 500PPS
Model Initial setting Auto refresh
LD62 8 14 (maximum number of parameters)
LD62D 8 14 (maximum number of parameters)