Mitsubishi Electronics 0 Universal Remote User Manual


 
90
(5) User devices
The input signal X3F is used by the system and is not available for users. If a user uses this signal (turning off and on), the
performance of the high-speed counter module is not guaranteed.
Device Description
D0 and D1 Present value
D2 and D3 Latch count value
D4 and D5 Sampling count value
D6 and D7 Periodic pulse count previous value
D8 and D9 Periodic pulse count present value
D10 Overflow status storage
M10 Initial setting completion signal
X40 Count start signal
LX40C6 (X40 to X4F)
X41 Present value read signal
X42 Coincidence output data setting signal
X43 Preset command signal
X44 Count stop signal
X45 Coincidence LED clear signal
X46 Counter function start signal
X47 Counter function stop signal
X48 Latch count data read signal
X49 Latch execution signal
X4A Sampling count data read signal
X4B Sampling count start signal
X4C Periodic pulse count data read signal
X4D Periodic pulse count start signal
Y50 Coincidence confirmation LED signal
LY41NT1P (Y50 to Y6F)
Y51 Overflow occurrence confirmation LED signal
X30 Module READY
LD62 (X/Y30 to X/Y3F)
X31 CH1 Counter value large (point No.1)
X32 CH1 Counter value coincidence (point No.1)
X33 CH1 Counter value small (point No.1)
X34 CH1 External preset request detection
X35 CH1 Counter value large (point No.2)
X36 CH1 Counter value coincidence (point No.2)
X37 CH1 Counter value small (point No.2)
Y30 CH1 Coincidence signal No.1 reset command
Y31 CH1 Preset command
Y32 CH1 Coincidence signal enable command
Y33 CH1 Down count command
Y34 CH1 Count enable command
Y35 CH1 External preset detection reset command
Y36
CH1 Counter function selection start
command
Y37 CH1 Coincidence signal No.2 reset command