Special installation (When the display is put in a box)
3.4.4 When the display is put in a box
Operating this display in confined spaces is not recommended.
If the display is to be used in a confined space, observe the following conditions shown in the drawing below:
A 50
B 50
C 10
D 50
Use a mesh with aperture efficiency of 50 % or more.
If hot air remains in the enclosed space, the temperature may rise causing a malfunction or fire. As a precaution, the
inner wall should have sufficient heat resistance or fire resistance.
Usage temperature conditions (BOX air temperature)
Ambient temperature: 0 °C to 35 °C
Rear view (the following area should be made of mesh)
A 50
B 50
C 10
D 50
A+
50 mm
A+
50 mm
A+
50 mm
B+
50 mm
B+
30 mm
100 mm
or more
100 mm
or more
Mesh with aperture efficiency
of 50 % or more
A+
50 mm
800 mm or more
800 mm or more
10 mm
10 mm
AA
BB
CD
Exhaust side Intake side
Outside air temperature
measuring point
: Thermometer