RS-232C Adjustment Mode
5.5.4 About the GET commands
What are GET commands?
These commands are used to transmit adjustment data and other information to PCs from a microcomputer in the
plasma display.
The This information is transmitted in ASCII code.
NOTE: Command names are given in parentheses< >.
1) <GPS> (GET POSITION DATA) — SCREEN parameters are issued in the following formats.
(1) STX (02H)
(2) <CFR>: Adjustment data for CLK FRQ (3 bytes)
(3) <CPH>: Adjustment data for CLK PHS (3 bytes)
(4) <HPS>: Adjustment data for H POSI (3 bytes)
(5) <VPS>: Adjustment data for V POSI (3 bytes)
(6) ETH (03H)
NOTES: • This command is invalid if the input function is INPUT 1.
When the input function is INPUT 2, or INPUT 3 or 4 and in the VIDEO setting, the issued CLK PHASE
adjustment data is the dummy data.
2) <GWB> (GET W/B DATA) — PICTURE and WHITE BALANCE parameters are issued in the following formats:
(1) STX (02H)
(2) <CNT>: Adjustment data for CONTRAST (3 bytes)
(3) <BRT>: Adjustment data for BRIGHT (3 bytes)
(4) <RHI>: Adjustment data for R HIGH (3 bytes)
(5) <GHI>: Adjustment data for G HIGH (3 bytes)
(6) <BHI>: Adjustment data for B HIGH (3 bytes)
(7) <RLW>: Adjustment data for R LOW (3 bytes)
(8) <GLW>: Adjustment data for G LOW (3 bytes)
(9) <BLW>: Adjustment data for B LOW (3 bytes)
(10) <COL>: Adjustment data for COLOUR (3 bytes)
(11) <TNT>: Adjustment data for TINT (3 bytes)
(12) <SHP>: Adjustment data for SHARP (3 bytes)
(13) <DTL>: Adjustment data for DETAIL (3 bytes)
(14) Dummy data (3 bytes)
(15) Dummy data (3 bytes)
(16) Dummy data (3 bytes)
(17) Dummy data (3 bytes)
(18) Dummy data (3 bytes)
(19) Dummy data (3 bytes)
(20) Dummy data (3 bytes)
(21) Dummy data (3 bytes)
(22) ETX (03H)
NOTE: When the input function is INPUT 3 or 4 and in the RGB setting, the adjustment data for COLOUR, TINT,