Before Beginning Adjustments
Action
= Enters Menu mode.
At this time, the only available RS-232C commands are:
<AJY>
<POF>
= Menu mode is disabled and RS-232C adjustment mode
is activated. At this time, only the following options are
available from the remote(or the operating panel of the
main unit):
Power switch
MENU button
KEY LOCK/UNLOCK button
3) Integrator Mode
This mode provides adjustment functions for the integrator.
White balance adjustment and various other setting items are available in addition to those in Menu mode.
Refer to “5.4 Integrator Mode” for further details.
4) RS-232C Adjustment Mode
This mode enables various adjustments and settings using a PC.
Some adjustment items are available only in this mode.
Refer to “5.5 RS-232C Adjustment Mode” for further details.
Combination use of remote, Unit operation panel, and PC.
5.1.2 Combination in use of remote, unit operating panel, and PC
The remote, and the operating panel of the main unit may be used together.
Example: You can enter Menu mode through the operating panel of the main unit, then make adjustments
using the remote.
Depending on which has transmitted the more recent command, either the remote or the operating panel(of the
main unit), or RS-232C may originate the command currently in effect.
Example: Operation
Press the MENU button on the remote
(or on the operating panel of the main
unit)
Now, issue an <AJY> command from
a PC.
NOTE: The remote does not have a KEY LOCK/UNLOCK button.