Pioneer PDP-501MX Flat Panel Television User Manual


 
92
Integrator Mode
Screen 1
]
MENU – –
WHITE BALANCE
SCREEN
3ADDITIONAL SET UP
TOTAL INITIALIZE
PICTURE
Screen 2
]
ADDITIONAL SET UP – –
COLOUR MODE : 1
3BAUD RATE : 4800BPS
HOUR METER : 00123
MIRROR MODE : OFF
EXIT
STD-RGB : OFF
SIDE MASK ADJ.
1 Enter Integrator mode (refer to “5.4.1 About Integrator
Mode”).
The ID number of the set of adjustment items will be
indicated in the upper right corner of the screen, where
“– –” is displayed in the illustration.
Select ADDITIONAL SET UP.
2 Move the cursor to BAUD RATE and select the desired value
with the SET button.
You can cycle through the available values by repeatedly
pressing the SET button: 1200BPS = 2400BPS = 4800BPS
= 9600BPS = 19200BPS =
BAUD RATE applies to each input (INPUTs 1-4) without
exception. All inputs are immediately switched to the baud
rate set in step 2.
Select EXIT in screen 2 to return to screen 1.
5) Setting the Baud Rate
When controlling or adjusting the unit from a PC, the RS-232C port can be set to one of five baud rates: 1200, 2400,
4800, 9600 and 19200 bps. The factory-preset value is 4800 bps.
Set the unit baud rate to match that of the PC in use. With long RS-232C cables, we recommend using lower baud
rates.