Special Installation (Mounting to fitting)
3.4 Special Installation
The unit can be hung from or embedded in a wall, but such special installations impose additional limitations on
operating temperatures and other operational factors. Examine installation methods and the ambient conditions for
your installation site while referring to paragraphs 3.1 to 3.3 in this manual.
Measurements discussed in this manual assume the following conditions:
A 100% white input is supplied.
Sufficient aging has been completed.
Make all measurements under identical conditions. The aging period required for correct measurement will be two
and a harf hours, depending on the space available at the installation site.
3.4.1 Mounting to fittings
Observe the following guidelines when mounting the unit to fittings. Notes 2 to 7 apply to all cases of mounting-to-
fitting.
1 During mounting to fitting, keep the space around the unit free of all objects and obstructions.
2 Any unit deformation/warping occurring as a result of installation should be less than 1 mm.
3 Never block or cover openings, aside from those shown as blocked on the page to the right.
4 The fittings should have a thickness of less than 20 mm. (This limit does not apply to fittings in examples 2 and 4
in the page to the right.)
5 L-shaped fittings should have a thickness of less than 100 mm.
6 The strength of the fittings must be adequate to bear the weight of the display.
7 Take precautions to avoid sharply bending the power cable.
* Operating Temperature Restrictions
Ambient temperature: 0 to 40 °C
* Operating Temperature Restrictions for Upside-Down Installations
• Ambient temperature: 0 to 35 °C
This method of installation should be avoided in cases illustrated by examples 1 and 4 above.
Maximum allowable deformation/
warping is 1 mm.
1mm MAX
Less than
100 mm
L-shaped fitting
Less than
20 mm
Less than
20 mm
No thickness limitations
in examples 2 and 4 on
the page to the right
Arrange the power cable
so that minimum stress is
placed on it.
No thickness limitations
in examples 2 and 4 on
the page to the right